首页 / 院系成果 / 成果详情页

Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth  期刊论文  

  • 编号:
    B01E76C5D2D52AA7ED5A125815508990
  • 作者:
    Qian, Tianwei(钱天威)#[1,2,3,4,5]Du, Jingxiao#[1,2,3,4,5]Ren, Ruixia[6];Zhou, Hao[1,2,3,4,5];Li, Haiyan*[6]Zhang, Zhihua(张志华)*[1,2,3,4,5,7]Xu, Xun(许迅)[1,2,3,4,5]
  • 语种:
    英文
  • 期刊:
    OPHTHALMIC RESEARCH ISSN:0030-3747 2023 年 66 卷 1 期 (319 - 319) ; 2023 JAN 3
  • 收录:
  • 摘要:

    Introduction: To evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).Methods: This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume (ACV) and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman''s correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively.Results: All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (P = 0.0003). The mean ECD and vault was 2855.76 +/- 270.82 cells/mm2 and 388.01 +/- 135.28 mu m at the last follow-up, respectively. The vault and C-ICL were significantly associated with Delta ECD (all P < 0.01). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (P < 0.001, OR = 14.739).Conclusions: ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.

  • 推荐引用方式
    GB/T 7714:
    Qian Tianwei,Du Jingxiao,Ren Ruixia, et al. Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth [J].OPHTHALMIC RESEARCH,2023,66(1):319-319.
  • APA:
    Qian Tianwei,Du Jingxiao,Ren Ruixia,Zhou Hao,&Xu Xun.(2023).Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth .OPHTHALMIC RESEARCH,66(1):319-319.
  • MLA:
    Qian Tianwei, et al. "Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth" .OPHTHALMIC RESEARCH 66,1(2023):319-319.
  • 入库时间:
    1/30/2023 10:57:05 AM
  • 更新时间:
    1/30/2023 10:57:05 AM
  • 条目包含文件:
    文件类型: , 文件大小:
    正在加载全文
浏览次数:48 下载次数:0
浏览次数:48
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部